How to Read a Submersible Pump Curve Before Selection

Release Time: 2026-10-29
Read: 22 views
Share:
Table of Contents

A pump curve should answer more than one question.

It should show whether the pump can deliver the required flow and head, but it should also indicate how efficiently it will operate, how much power it will absorb and whether the selected duty point is inside a reliable operating range.

Two pumps may both be described as suitable for 100 m³/h at 80 m head. That does not make them equally good selections. One may operate close to its best efficiency point, while the other reaches the same duty only near the end of its curve. Their energy use, motor loading and expected service life may be very different.

For this reason, buyers should request the actual performance curve for the proposed pump—not only a model number and a single flow-and-head figure.

What Information Does a Pump Curve Show?

A complete centrifugal or submersible pump curve normally includes several related curves:

  • Flow versus head
  • Pump efficiency
  • Pump input or shaft power
  • Best efficiency point
  • Recommended operating range
  • NPSH requirement, where applicable
  • Impeller diameter, stage number or hydraulic configuration
  • Pump speed and electrical frequency

The horizontal axis normally represents flow. Common units include:

  • m³/h
  • L/s
  • US gpm

The vertical axis normally represents head. Common units include:

  • Metres
  • Feet

Always confirm the units before comparing two curves. A curve in US gallons per minute and feet cannot be compared directly with one in cubic metres per hour and metres.

Confirm That You Have the Correct Curve

Before looking at the duty point, check the identification information printed on the curve.

At minimum, confirm:

  • Exact pump model
  • Number of stages
  • Impeller diameter or hydraulic version
  • Rotational speed
  • Frequency: 50 Hz or 60 Hz
  • Tested or rated liquid
  • Curve revision or publication date

This is particularly important for multistage deep-well pumps. Two pumps may use the same hydraulic series but have different numbers of stages. Their flow ranges may be similar, while their available head is significantly different.

A curve prepared for 60 Hz operation should not be used to select a pump that will operate at 50 Hz. Pump speed affects flow, head and power. The correct 50 Hz or 60 Hz performance data must be used.

For deep-well applications, the curve should match the exact pump configuration offered in the quotation. Review the available submersible well pump range before comparing individual models.

Start with a Calculated Duty Point

The pump curve cannot correct an inaccurate system calculation.

Before selecting a pump, determine:

  • Required flow
  • Total dynamic head
  • Minimum and maximum expected water levels
  • Required outlet pressure
  • Pipe losses
  • Expected operating range

If total dynamic head has not yet been calculated, refer to How to Calculate Total Dynamic Head for a Submersible Pump.

A duty point should always contain both flow and head.

For example:

Required flow: 100 m³/h
Required total dynamic head: 84 m

Mark 100 m³/h on the horizontal axis. Move vertically until reaching 84 m on the head axis. The point where these two values meet is the required duty point.

The selected pump curve should pass through or close to this point.

Understanding the Flow-Head Curve

The main performance curve is usually called the Q-H curve:

  • Q means flow.
  • H means head.

For most centrifugal pumps, available head decreases as flow increases.

At low flow, the pump produces more head. As the system allows more water to pass, the operating flow increases and the available head falls.

The pump does not independently decide to operate at one point on its curve. The actual operating point is determined by the interaction between the pump and the piping system.

The system creates resistance through:

  • Static elevation
  • Required discharge pressure
  • Pipe friction
  • Valves and fittings
  • Filters and other equipment

The pump curve and system curve intersect at the actual operating point.

Opening a valve reduces system resistance and generally moves the operating point toward higher flow and lower head. Closing a valve increases resistance and generally moves it toward lower flow and higher head.

This is why a catalogue curve should never be read as a list of separate pump capacities. It describes how one pump behaves under different system resistance conditions.

A Practical Curve Example

Assume a project requires:

Required flow: 100 m³/h
Required TDH: 84 m

A proposed pump has the following approximate curve points:

  • 80 m³/h at 92 m head
  • 100 m³/h at 85 m head
  • 120 m³/h at 75 m head

The required point of 100 m³/h at 84 m is close to the published curve, so the pump appears hydraulically suitable.

That is only the first check.

The next questions are:

  • Is 100 m³/h close to the best efficiency point?
  • What is the pump input power at this flow?
  • Does the motor remain adequately sized at higher flow?
  • What happens when the well water level changes?
  • Is the point inside the recommended continuous operating range?

A curve that reaches the required point is not automatically a complete selection.

Best Efficiency Point

The best efficiency point, or BEP, is the flow and head at which a pump reaches its maximum hydraulic efficiency for a given speed and hydraulic configuration.

Near BEP, water enters and leaves the impeller with relatively low hydraulic disturbance. Internal recirculation, vibration and uneven hydraulic loading are generally lower than they are far away from BEP.

For reliable continuous operation, the normal duty point should be reasonably close to BEP.

Suppose the example pump has:

BEP flow: 105 m³/h
BEP head: 82 m
Maximum pump efficiency: 78%

The required duty of 100 m³/h at 84 m is close to BEP. This would generally be a better selection than a pump whose BEP is 160 m³/h but is being forced to operate at 100 m³/h.

Do not select a pump from the highest efficiency number alone. The important question is the efficiency at the actual operating point.

Preferred and Allowable Operating Regions

The preferred operating region, or POR, is the range around BEP in which hydraulic efficiency and operating reliability are not substantially degraded.

A wider range may be shown as the allowable operating region, or AOR. Operation within the AOR may be acceptable, but it is not necessarily the best condition for long-term continuous duty.

The exact limits depend on the pump design. They should be confirmed by the manufacturer rather than assumed from a general percentage.

Operating too far to the left of BEP means the pump is producing low flow at relatively high head. Possible consequences include:

  • Internal recirculation
  • Increased hydraulic loading
  • Vibration
  • Local heating
  • Reduced bearing and seal life
  • Unstable operation

Operating too far to the right means high flow at lower head. Possible consequences include:

  • Motor overload
  • Excessive water velocity
  • Increased NPSH requirement
  • Cavitation risk
  • Excessive axial or radial loading
  • Rapid well drawdown

A quotation should identify whether the proposed duty point is intended for continuous operation or only short-duration operation.

Reading the Efficiency Curve

Efficiency may be shown as a separate line or as efficiency contours across the flow-head chart.

It is important to identify what the published value represents.

The curve may show:

  • Pump hydraulic efficiency
  • Pump and motor combined efficiency
  • Overall wire-to-water efficiency

These values are not interchangeable.

Pump hydraulic efficiency compares hydraulic output with power delivered to the pump shaft. Overall efficiency also includes motor losses and, where applicable, losses in cables, drives and controls.

If the curve shows a pump efficiency of 78%, that does not mean 78% of the electrical power entering the control panel reaches the water.

When comparing quotations, ask each supplier to state clearly whether the efficiency figure refers to the pump only or the complete pump-and-motor unit.

Estimating Hydraulic Power

For clean water, hydraulic output power can be estimated with the following plain-text formula:

Hydraulic Power in kW = Flow in m³/h × Head in m × 0.002725

For the example duty point:

Flow = 100 m³/h
Head = 84 m

Hydraulic Power = 100 × 84 × 0.002725

Hydraulic Power = 22.9 kW

This is the power transferred to the water. It is not the required motor rating.

If pump efficiency at the duty point is 78%:

Pump Shaft Power = Hydraulic Power ÷ Pump Efficiency

Pump Shaft Power = 22.9 ÷ 0.78

Pump Shaft Power = 29.4 kW

If motor efficiency is 92%:

Approximate Electrical Input = Pump Shaft Power ÷ Motor Efficiency

Approximate Electrical Input = 29.4 ÷ 0.92

Approximate Electrical Input = 32.0 kW

These calculations are useful for checking a quotation, but final motor selection should be based on the manufacturer’s verified power curve across the complete expected operating range.

For liquids with a density different from water, include specific gravity:

Hydraulic Power in kW = Flow in m³/h × Head in m × Specific Gravity × 0.002725

Reading the Power Curve

The power curve may be labelled:

  • P2
  • Shaft power
  • Pump input power
  • Brake power
  • Absorbed power

The exact meaning should be confirmed on the data sheet.

Do not check power only at the specified duty point.

In many centrifugal pump designs, absorbed power increases as flow moves to the right. A pump that requires 29 kW at the rated point may require more power if the system head falls and flow increases.

The motor should be checked against the maximum absorbed power within the expected operating range, not only against the power calculated at one point.

Also confirm:

  • Motor rated output
  • Motor efficiency
  • Service factor, if applicable
  • Starting method
  • Voltage and frequency
  • Permitted number of starts per hour
  • Cable length and voltage drop
  • Variable-frequency-drive compatibility, where required

A larger motor is not a substitute for correct hydraulic selection. It may prevent overload, but it does not correct operation outside the pump’s reliable range.

Check Both Minimum and Maximum System Head

A deep-well pump rarely operates at exactly one head throughout its service life.

System head may change because of:

  • Seasonal groundwater variation
  • Well drawdown
  • Tank water level
  • Filter condition
  • Valve position
  • Pipeline extension
  • Several outlets operating at once
  • Changes in discharge pressure

Consider the earlier duty point of 100 m³/h at 84 m.

If the dynamic water level falls by 5 m, the required head may increase to approximately 89 m. The operating point moves left on the pump curve, producing less flow.

If the water level rises by 8 m, the system head may fall to approximately 76 m. The operating point moves right, producing more flow and potentially requiring more motor power.

The selected curve should be checked at:

  • Normal operating condition
  • Maximum expected head
  • Minimum expected head

For projects with large variations in water level or high head, a specialized pump such as the QJT Mine Submersible Pump may require a broader operating review.

Shutoff Head

Shutoff head is the head produced when flow is zero.

It is found at the far left of the Q-H curve.

A pump should not operate continuously against a closed valve. With no flow, the liquid inside the pump can heat rapidly and internal hydraulic forces can increase.

Shutoff head is still important when checking:

  • Maximum pipeline pressure
  • Valve pressure class
  • Flange pressure rating
  • Pressure-tank protection
  • Pressure-switch settings
  • Water-hammer risk

Convert shutoff head into approximate pressure when checking the system.

For water:

Pressure in bar = Head in metres ÷ 10.2

If shutoff head is 120 m:

Pressure = 120 ÷ 10.2

Pressure = approximately 11.8 bar

Static pressure from the installation may also need to be considered when checking the pressure rating of individual components.

Maximum-Flow or Runout Condition

The far-right side of the curve represents high flow and low head. The extreme end is often called runout.

Operation near runout may result in:

  • Motor overload
  • Excessive well drawdown
  • Increased vibration
  • High water velocity
  • Cavitation or insufficient inlet pressure
  • Operation outside the tested range

Do not assume the last point shown on a curve is a recommended continuous-duty point.

Ask the supplier to identify the maximum permitted continuous flow for the selected pump.

NPSH and Submergence

NPSH is commonly associated with dry-installed centrifugal pumps, but inlet conditions still matter for a submersible pump.

A deep-well pump does not have an external suction pipe in the conventional sense. However, the pump inlet must remain adequately submerged under all operating conditions.

Check:

  • Lowest expected dynamic water level
  • Pump inlet position
  • Required minimum submergence
  • Well drawdown at maximum flow
  • Water temperature
  • Inlet velocity
  • Possibility of vortex formation
  • Sand or gas entering the pump

The pump should not be installed based only on static water level. The required submergence must remain available when the pump is operating at its actual flow.

If the manufacturer supplies an NPSH or minimum-submergence requirement, check it at the highest expected operating flow, not only at the rated flow.

Curve Corrections for Different Liquids

Published curves are normally based on clean water at a specified temperature and rotational speed.

If the pumped liquid has different properties, corrections may be required.

Important properties include:

  • Density
  • Viscosity
  • Temperature
  • Solids content
  • Gas content
  • Chemical composition

Higher density increases required power even when head in metres remains similar.

Higher viscosity can reduce flow, head and efficiency while increasing power demand.

Water containing sand or suspended solids can also affect hydraulic performance and wear. Material selection should therefore be reviewed separately from the hydraulic curve.

For corrosive groundwater, compare the standard QJ range with an SS304 deep-well submersible pump only after checking the water analysis and the exact material configuration.

Variable-Speed Operation

A variable-frequency drive changes pump speed and therefore shifts the pump curve.

For a limited speed change, the affinity laws provide an approximate relationship:

Flow changes in direct proportion to speed.

Head changes approximately with the square of speed.

Power changes approximately with the cube of speed.

For example, reducing speed to 90% of the original value gives approximately:

New flow = Original flow × 0.90

New head = Original head × 0.90²

New power = Original power × 0.90³

These relationships are useful for preliminary analysis, but the final selection should use manufacturer-provided variable-speed curves.

For submersible motors, also confirm:

  • Permitted frequency range
  • Minimum cooling flow
  • Motor insulation suitability
  • Cable length
  • VFD output-filter requirements
  • Minimum operating speed
  • Starting and acceleration settings

Parallel Pumps Do Not Automatically Double the Flow

When two identical pumps operate in parallel, their flows combine at the same head.

However, the total system flow will not normally be exactly twice the single-pump flow because pipeline friction increases as flow rises.

The correct operating point must be found by combining the parallel pump curve with the system curve.

When pumps operate in series, their heads combine at approximately the same flow. Series and parallel arrangements should therefore be evaluated differently.

For multiple-pump projects, request curves for:

  • One pump operating
  • All duty pumps operating
  • Duty and standby arrangement
  • Minimum-demand condition
  • Maximum-demand condition

Catalogue Curve, Published Curve and Tested Curve

Not all pump curves provide the same level of detail.

A range chart is used to identify which pump family may cover the duty point.

A published performance curve provides more detailed flow, head, efficiency and power information for a model or hydraulic size.

A certified or factory-tested curve records the measured performance of the specific pump or agreed production configuration.

For an important project, the purchase specification should state whether the buyer requires:

  • Catalogue performance data
  • Standard factory test
  • Witnessed performance test
  • Certified test report
  • Agreed acceptance tolerance
  • Test standard and acceptance grade

Do not assume that a general catalogue curve is the test result for the exact pump being purchased.

What Buyers Should Request with a Pump Quotation

A technically complete quotation should include:

  • Exact pump model
  • Number of stages
  • Impeller or hydraulic configuration
  • Rated flow and head
  • Marked duty point
  • Pump performance curve
  • Efficiency at the duty point
  • Best efficiency point
  • Recommended operating range
  • Absorbed power at the duty point
  • Maximum absorbed power in the operating range
  • Motor rated output
  • Pump and motor speed
  • Voltage and frequency
  • Shutoff head
  • Maximum permitted flow
  • NPSH or minimum-submergence requirement
  • Test standard, where applicable
  • Material list
  • Curve revision or document number

If a supplier provides only one flow figure, one head figure and one motor rating, the quotation is not yet complete enough for a proper technical comparison.

A Better Way to Compare Two Pump Quotations

Suppose two suppliers offer pumps for 100 m³/h at 84 m.

Pump A operates near its BEP, has acceptable efficiency and remains within its recommended range as the water level changes.

Pump B reaches the required point near the left edge of its curve, requires throttling during normal operation and moves outside its preferred range when the water level falls.

Both quotations may show the same flow and head. They are not technically equivalent.

Before comparing price, compare:

  • Position of the duty point
  • Efficiency at the duty point
  • Power across the operating range
  • Distance from BEP
  • Minimum and maximum permitted flow
  • Water-level variation
  • Material configuration
  • Test requirements
  • Motor and control arrangement

The lowest purchase price is not necessarily the lowest operating cost or the lowest project risk.

Information to Send for Curve Selection

Provide the following information when requesting a marked pump curve:

  • Required flow
  • Calculated total dynamic head
  • Static water level
  • Dynamic water level
  • Expected seasonal water-level variation
  • Pump setting depth
  • Well diameter
  • Pipe diameter and total length
  • Required discharge pressure
  • Liquid temperature
  • Water analysis
  • Sand or solids content
  • Voltage and frequency
  • Operating hours
  • Control method
  • Number of duty and standby pumps

A complete duty specification allows the manufacturer to select the correct hydraulic configuration and mark the expected operating point clearly.

Request a Pump Curve and Model Selection

Send your required flow, total dynamic head, water levels, pipe details, liquid conditions and power supply to Shanghai Weihu Pump Industry Co., Ltd.

We can review the operating range, propose a suitable pump configuration and provide the corresponding performance data for technical evaluation.