Two deep-well pump quotations may show the same flow, head and motor power but still describe very different equipment.
The differences are often found in the pump curve, material configuration, motor design, cable length, test scope and included accessories. Comparing only the model name and total price can lead to unexpected costs after installation.
A fair comparison begins with one rule: every supplier must quote against the same operating data and supply scope.
1. Confirm That Every Supplier Used the Same Duty Point
Start by checking the required flow and total dynamic head.
Example:
Required flow: 100 m³/h
Required total dynamic head: 84 m
Do not accept a quotation that shows only:
- Maximum flow
- Maximum head
- A broad performance range
- Motor power without a rated duty point
Maximum flow and maximum head normally occur at different positions on the pump curve. They cannot be treated as one operating condition.
If suppliers used different dynamic water levels, pipe losses or outlet pressures, their quotations are not directly comparable.
Before requesting prices, prepare a complete Deep-Well Submersible Pump RFQ Checklist.
2. Request the Performance Curve
The quotation should include a curve for the proposed pump model and number of stages.
The required duty point should be marked clearly.
Check:
- Flow and head at the duty point
- Best efficiency point
- Efficiency at the duty point
- Recommended operating range
- Absorbed power
- Shutoff head
- Maximum permitted flow
- Rotational speed
- Frequency
- Number of stages
A pump that reaches the duty point near its best efficiency region is generally a better choice than one operating near the end of its curve.
Also check how the pump behaves when the dynamic water level changes. A falling water level increases the required head, while a rising water level may increase pump flow and motor loading.
For help interpreting the curve, see How to Read a Submersible Pump Curve Before Selection.
3. Compare Efficiency and Absorbed Power
Motor rating alone does not show how much electricity the pump will use.
A quotation may list a 37 kW motor, but the pump may absorb 28 kW, 32 kW or close to the full motor rating at the required duty point.
Ask suppliers to state:
- Pump efficiency at the duty point
- Pump absorbed power
- Motor rated output
- Motor efficiency
- Maximum absorbed power within the operating range
Confirm whether the published efficiency refers to:
- Pump hydraulic efficiency
- Pump-and-motor efficiency
- Overall wire-to-water efficiency
These values are different and should not be compared as if they were the same.
For continuous operation, a small efficiency difference can affect long-term electricity cost. However, an efficiency claim is useful only when it is tied to the actual duty point.
4. Compare Materials Component by Component
“Stainless-steel pump” is not a complete material description.
One quotation may provide a stainless-steel pump casing with a different shaft or motor casing. Another may use stainless steel for all major wetted components.
Request a material list covering:
- Discharge casing
- Pump bowls or diffusers
- Impellers
- Pump shaft
- Suction housing
- Inlet screen
- Motor casing
- Fasteners
- Mechanical seal
- Cable outer sheath
Also confirm the stainless-steel grade:
- SS304
- SS316
- SS316L
- Duplex stainless steel
- Other specified alloy
Material should be selected from water quality, not appearance or price alone. Chloride concentration, pH, temperature, sand and other corrosive substances should be reviewed before ordering.
For compatible clean-water conditions requiring stainless-steel construction, compare the proposed material list with the QJH SS304 Deep-Well Submersible Pump.
5. Check the Motor Specification
The motor specification should state:
- Rated power
- Rated voltage
- Frequency
- Number of phases
- Rated current
- Speed
- Insulation class
- Protection and cooling arrangement
- Starting method
- Permitted starts per hour
- Maximum installation depth
Confirm that the curve and motor are both based on the project frequency.
A 60 Hz curve should not be used to justify performance at 50 Hz unless corrected performance data are supplied.
If a variable-frequency drive will be used, request written confirmation of:
- Permitted frequency range
- Minimum operating speed
- Cooling requirements
- Cable limitations
- Required VFD output filter
- Motor insulation suitability
6. Compare Cable Length and Cable Size
Cable is often a major difference between quotations.
Check:
- Included cable length
- Cable cross-section
- Number of conductors
- Cable voltage rating
- Cable material
- Submersible cable joint
- Temperature and chemical resistance
A low quotation may include only a short motor lead rather than the full cable required to reach the control cabinet.
Cable size should be checked against motor current, starting method, cable length and acceptable voltage drop.
Ask whether the quotation includes:
- Full-length factory cable
- Cable joint kit
- Waterproof connection
- Separate grounding conductor
- Cable guards or fixing accessories
7. Define What Is Included in the Price
Write the supply boundary clearly.
Depending on the project, the quotation may include only the pump and motor, or it may also include:
- Power cable
- Control cabinet
- Check valve
- Riser pipe
- Flanges
- Cable clamps
- Water-level sensors
- Pressure sensor
- Spare parts
- Installation tools
- Export packing
Do not compare a bare pump price with a complete pumping package.
Also check whether the price includes:
- Factory testing
- Technical documents
- Packing
- Inland transport
- Freight
- Insurance
- Customs documents
The Incoterm must be shown, such as EXW, FOB, CFR or CIF, together with the named port or destination.
8. Confirm the Testing Scope
“Pump tested before delivery” is too general.
Ask what will actually be tested and what document will be supplied.
Possible requirements include:
- Routine electrical inspection
- Insulation-resistance test
- Hydraulic performance test
- Flow and head test
- Absorbed-power measurement
- Efficiency calculation
- Hydrostatic pressure test
- Mechanical integrity test
- Witnessed testing
- Certified performance report
For a critical project, specify the required test standard and acceptance grade before ordering. Do not wait until production is complete.
Also confirm whether the test applies to:
- The exact purchased pump
- One sample from the production batch
- A similar hydraulic model
- Catalogue data only
These are not equivalent.
9. Compare Technical Documents
A complete quotation should identify the documents supplied before production and before shipment.
Typical documents include:
- Pump performance curve
- General arrangement drawing
- Motor data sheet
- Material list
- Wiring diagram
- Installation manual
- Test report
- Packing list
- Spare-parts list
Check document language, units and approval procedure.
For custom projects, the buyer should approve the final drawing, material list and duty point before production begins.
10. Check Delivery, Warranty and Spare Parts
Delivery time should be defined from an agreed starting point, such as:
- Receipt of deposit
- Approval of technical documents
- Confirmation of materials
- Completion of inspection
Warranty terms should state:
- Warranty period
- Starting date
- Covered components
- Exclusions
- Claim procedure
- Responsibility for freight and replacement parts
Ask for a recommended spare-parts list for the expected operating period. The cheapest quotation may become more expensive if special parts are difficult to obtain later.
Warning Signs in a Pump Quotation
Review the quotation carefully if:
- The duty point is not marked on a curve.
- Maximum flow and maximum head are presented as one point.
- Material is described only as “stainless steel.”
- Motor voltage or frequency is missing.
- Cable length is not stated.
- Pump and motor efficiency are confused.
- Testing is promised without a named test scope.
- Accessories are shown in pictures but excluded from the price.
- Model number changes between quotation and technical sheet.
- Warranty wording is unclear.
These points do not automatically mean the supplier is unsuitable, but they should be clarified before issuing a purchase order.
A Simple Quotation Comparison Sheet
Use the same fields for every supplier:
Required duty point:
Proposed pump model:
Number of stages:
Duty-point efficiency:
Absorbed power:
Motor rated power:
Voltage and frequency:
Pump materials:
Motor casing material:
Cable size and length:
Included accessories:
Test standard and report:
Delivery time:
Warranty:
Incoterm:
Total price:
Any blank field should be confirmed before the commercial comparison is finalized.
Compare Technical Compliance Before Price
The correct order is:
- Confirm compliance with the required duty.
- Compare operating range and efficiency.
- Compare materials and motor specification.
- Compare cable, accessories and testing.
- Compare delivery and warranty.
- Compare price.
For standard groundwater projects, review the QJ Deep-Well Submersible Pump or browse the complete Submersible Well Pump range.
Request a Technical and Commercial Quotation
Send the required flow, total dynamic head, well data, water analysis, electrical supply and required test scope to Shanghai Weihu Pump Industry Co., Ltd.
We can prepare a quotation with the proposed model, material configuration, performance data and supply scope clearly identified.