How to Calculate Total Dynamic Head for a Submersible Pump

Release Time: 2026-10-24
Read: 28 views
Share:
Table of Contents

A submersible pump should not be selected from well depth alone.

The pump must produce enough head to lift water from the pumping water level, overcome resistance in the riser and discharge pipe, and still provide the required pressure at the delivery point. The sum of these requirements is called total dynamic head, commonly abbreviated as TDH.

Incorrect TDH is a common reason a newly installed pump fails to deliver the expected flow. A pump with insufficient head may produce too little water or fail to reach the discharge point. A heavily oversized pump can create excessive pressure, consume unnecessary power and operate outside its recommended range.

For a deep-well installation, the most important distinction is this:

The pump setting depth is not automatically the lifting head. The calculation normally starts from the dynamic water level while the pump is operating.

What Is Total Dynamic Head?

For most submersible pump applications, total dynamic head can be calculated as follows:

TDH = Elevation Head + Required Pressure Head + Pipe Friction Loss + Fitting and Valve Losses

Not every system includes all four components.

For example, when a pump transfers water from a well into an open tank, no additional pressure may be required at the delivery point. In that case, TDH consists mainly of elevation head and pipeline losses.

When the pump supplies a pressurized irrigation network, industrial pipeline or pressure tank, the required outlet pressure must also be included.

Step 1: Confirm the Required Flow Rate

TDH cannot be calculated accurately without a design flow rate.

Pipeline friction changes with flow. The same pipe may produce a relatively small pressure loss at 40 m³/h and a much larger loss at 100 m³/h. For this reason, it is incomplete to specify only that a pump requires “80 metres of head.”

A proper duty point should always contain both flow and head:

Required flow: 100 m³/h

Required TDH: 84 m

The required flow should be based on the actual project demand, such as:

  • Agricultural irrigation demand
  • Tank-filling time
  • Municipal or domestic water consumption
  • Industrial process demand
  • Mine or construction-site water inflow
  • Number of outlets operating at the same time
  • Number of pumps operating simultaneously

Avoid adding several flow requirements together unless they will genuinely occur at the same time. This is a frequent cause of oversized pumps.

Step 2: Identify the Correct Water Level

Three different depths are often confused during deep-well pump selection.

Static Water Level

The static water level is the distance from ground level to the water surface before the pump starts.

Dynamic Water Level

The dynamic water level, also called the pumping water level, is the water level after the pump has operated at the required flow long enough for the well to stabilize.

Pump Setting Depth

The pump setting depth is the physical depth at which the submersible pump is installed.

These three values are not interchangeable.

Consider the following well:

  • Total well depth: 120 m
  • Static water level: 22 m below ground
  • Dynamic water level: 38 m below ground
  • Pump setting depth: 75 m below ground

If the pump delivers water at ground level into an open tank, the basic lifting height is approximately 38 m. It is not 75 m and it is not 120 m.

The pump is installed below the dynamic water level to maintain sufficient submergence. The water above the pump inlet provides hydrostatic pressure, so the full pump setting depth should not be used as the elevation head.

However, the complete riser-pipe length must still be included when calculating pipe friction. In this example, the vertical pipe from the pump to the wellhead is approximately 75 m long.

For standard groundwater applications, review the QJ Deep-Well Submersible Pump.

Step 3: Calculate the Elevation Head

Elevation head is the vertical distance between the pumping water level and the final delivery point.

For a deep-well installation, the starting point is normally the dynamic water level.

The final point depends on where the water is delivered:

  • For an open tank, use the highest operating water level inside the tank.
  • For an open discharge pipe, use the elevation of the pipe outlet.
  • For a pressurized pipeline, use the elevation of the specified pressure-measurement point.
  • For an irrigation system, use the elevation of the highest or hydraulically most demanding outlet.

Assume that:

  • Dynamic water level is 38 m below ground.
  • Discharge point is 12 m above ground.

The elevation head is:

Elevation Head = 38 m + 12 m

Elevation Head = 50 m

Horizontal pipe length does not increase elevation head, but it does increase pipe friction.

Step 4: Convert the Required Pressure into Head

When the receiving system requires pressure, that pressure must be added to TDH.

For clean water at normal ambient temperature, the following conversions can be used:

  • 1 bar is approximately 10.2 m of water head.
  • 2 bar is approximately 20.4 m of water head.
  • 2.5 bar is approximately 25.5 m of water head.
  • 3 bar is approximately 30.6 m of water head.
  • 100 kPa is approximately 10.2 m of water head.
  • 1 psi is approximately 0.703 m of water head.

If the required pressure at the delivery point is 2.5 bar:

Pressure Head = 2.5 × 10.2

Pressure Head = 25.5 m

Do not add pressure head when the pump is simply discharging into an open tank at atmospheric pressure.

For liquids other than clean water, pressure-to-head conversion should use the actual liquid density.

Step 5: Calculate Water Velocity in the Pipe

Water velocity is required when calculating pipe friction.

First, convert flow from cubic metres per hour to cubic metres per second:

Flow in m³/s = Flow in m³/h ÷ 3,600

For a flow of 100 m³/h:

Flow = 100 ÷ 3,600

Flow = 0.0278 m³/s

Next, calculate the internal cross-sectional area of the pipe:

Pipe Area = 3.1416 × Internal Diameter² ÷ 4

For a pipe with an actual internal diameter of 0.125 m:

Pipe Area = 3.1416 × 0.125² ÷ 4

Pipe Area = 0.01227 m²

Water velocity is then calculated as:

Water Velocity = Flow ÷ Pipe Area

Water Velocity = 0.0278 ÷ 0.01227

Water Velocity = 2.26 m/s

Always use the actual internal pipe diameter—not only the nominal pipe size.

A DN125 steel pipe, PVC pipe and polyethylene pipe may have different internal diameters because their wall thicknesses and pressure ratings are different. A smaller internal diameter increases water velocity and pipe friction.

Step 6: Calculate Straight-Pipe Friction Loss

Straight-pipe friction can be calculated using the Darcy-Weisbach method:

Pipe Friction Loss = Friction Factor × (Pipe Length ÷ Internal Diameter) × Velocity Head

Velocity head is calculated as:

Velocity Head = Water Velocity² ÷ (2 × 9.81)

Using the example velocity of 2.26 m/s:

Velocity Head = 2.26² ÷ 19.62

Velocity Head = 0.26 m

Assume the following:

  • Total straight-pipe length: 150 m
  • Actual internal pipe diameter: 0.125 m
  • Darcy friction factor: 0.022
  • Velocity head: 0.26 m

The straight-pipe friction loss is:

Pipe Friction Loss = 0.022 × (150 ÷ 0.125) × 0.26

Pipe Friction Loss = 6.9 m

The friction factor of 0.022 is used only for this calculation example. The actual value depends on:

  • Pipe material
  • Internal pipe roughness
  • Pipe diameter
  • Water velocity
  • Reynolds number
  • Liquid viscosity
  • Condition and age of the pipeline

For a final project calculation, use a recognized pipe-friction calculator, engineering software or verified friction-loss table.

The total pipe length should include:

  • Vertical riser pipe inside the well
  • Wellhead pipework
  • Horizontal discharge pipe
  • Pipe leading to the tank or process
  • Any additional pipe before the specified delivery point

Do not calculate friction only from the wellhead to the tank. The riser pipe inside the well also contributes to friction loss.

Step 7: Add Losses from Valves and Fittings

Valves, elbows and other pipe components create additional resistance.

These losses can be calculated using resistance coefficients:

Fitting Loss = Total Resistance Coefficient × Velocity Head

Assume that the combined resistance coefficient of the valves and fittings is 5.5:

Fitting Loss = 5.5 × 0.26

Fitting Loss = 1.4 m

Components that may need to be included are:

  • Check valves
  • Gate valves
  • Butterfly valves
  • Globe valves
  • Elbows and bends
  • Tees
  • Reducers
  • Flow meters
  • Strainers
  • Non-return valves
  • Wellhead fittings
  • Heat exchangers
  • Process equipment

For large valves, strainers, meters and process equipment, use the manufacturer’s published pressure-loss data whenever possible.

Complete TDH Calculation Example

The project requires a submersible pump to deliver water from a borehole into a pressurized water-supply pipeline.

The known operating conditions are:

  • Required flow: 100 m³/h
  • Dynamic water level: 38 m below ground
  • Discharge-point elevation: 12 m above ground
  • Required pressure at discharge point: 2.5 bar
  • Pump setting depth: 75 m
  • Total pipe length: 150 m
  • Actual pipe internal diameter: 125 mm
  • Pipe friction loss: 6.9 m
  • Valve and fitting loss: 1.4 m
  • Pumped liquid: Clean water

The separate head components are:

  • Elevation head: 50 m
  • Required pressure head: 25.5 m
  • Straight-pipe friction loss: 6.9 m
  • Valve and fitting loss: 1.4 m

The total dynamic head is:

TDH = 50 + 25.5 + 6.9 + 1.4

TDH = 83.8 m

The preliminary pump duty point is therefore:

Required Duty Point: 100 m³/h at approximately 84 m TDH

This is the duty point that should be marked on the pump performance curve.

Account for Changes in Dynamic Water Level

A well’s dynamic water level may change with season, pumping duration and aquifer recharge.

Assume the water level may fall another 5 m during the dry season.

The maximum-head condition becomes:

Maximum TDH = 83.8 m + 5 m

Maximum TDH = 88.8 m

The pump should therefore be checked at approximately:

100 m³/h at 89 m TDH

The minimum-head condition must also be checked.

If the dynamic water level rises from 38 m to 30 m below ground, the TDH becomes:

Minimum TDH = 83.8 m − 8 m

Minimum TDH = 75.8 m

At this lower head, the pump may move farther to the right on its performance curve and produce more flow. The manufacturer should verify that:

  • Flow does not exceed the recommended operating range.
  • Motor input power remains below the rated limit.
  • Pipeline pressure remains acceptable.
  • Water velocity remains within the system design limit.
  • The well can supply the increased flow without excessive drawdown.

A technically correct pump selection should consider both maximum-head and minimum-head conditions.

Do Not Add an Arbitrary Safety Margin

Adding 10% or 20% to the calculated head without identifying the uncertainty can result in an oversized pump.

Instead of applying a general safety factor, identify the actual variables:

  • Seasonal change in dynamic water level
  • Unconfirmed pipe internal diameter
  • Future pipeline extension
  • Possible increase in required pressure
  • Changes in water demand
  • Additional valves or filtration equipment
  • Pipe ageing and internal deposits

If the dynamic water level may fall by 5 m, add 5 m. If a future filter is expected to create a 3 m loss, add 3 m.

This produces a defensible design condition instead of an unexplained percentage.

Why TDH Changes with Flow

Elevation head and required delivery pressure may remain relatively constant, but pipe friction changes with flow.

In many turbulent water-pumping systems, friction loss changes approximately with the square of flow.

This means that doubling the flow can increase friction loss by roughly four times.

For example:

  • Pipe loss at 50 m³/h may be approximately 2 m.
  • In the same pipe, loss at 100 m³/h may approach 8 m.

The exact values depend on pipe diameter, material, length and fittings, but the relationship explains why increasing pump size does not always produce a proportional increase in delivered flow.

The additional pump head may be consumed by higher pipeline resistance.

How to Check the Pump Performance Curve

After calculating the required flow and TDH, request a performance curve for the proposed pump.

The curve should show the selected duty point. Check the following items.

Head at the Required Flow

The pump curve must pass through or close to the required duty point.

Do not select a pump only because the nominal flow and head shown in the model number appear similar to the project requirement.

Best Efficiency Region

The normal operating point should be reasonably close to the pump’s best efficiency region. Continuous operation at the far left or far right of the curve can reduce efficiency and reliability.

Maximum and Minimum TDH

Check the pump at the lowest and highest expected dynamic water levels.

If discharge pressure varies, the minimum and maximum pressure conditions should also be evaluated.

Absorbed Power

Confirm the pump’s absorbed power across the expected operating range.

A pump may require more motor power when system head falls and flow increases. The motor must not overload at the minimum-head condition.

Shutoff Head

Shutoff head is the pressure produced when the pump operates at zero flow.

The pipeline, valves, fittings and pressure-control equipment must be able to withstand this condition.

Recommended Operating Range

Ask the manufacturer to mark the recommended continuous operating range on the curve.

Not every point shown on the complete pump curve is suitable for continuous operation.

Common TDH Calculation Mistakes

Using Total Well Depth as Pump Head

A 150 m deep well does not automatically require a pump with 150 m of head.

Use the dynamic water level, discharge elevation, required pressure and system losses.

Using Static Water Level

Static water level is measured before pumping. The water level normally falls during operation.

The pump should be selected using the expected dynamic water level at the required flow.

Adding Pump Setting Depth Twice

Pump setting depth affects pipe length, cable length and pump submergence.

It should not automatically be added again as elevation head.

Ignoring Outlet Pressure

A pump may lift water to the discharge elevation but still fail to provide sufficient pressure for sprinklers, filtration equipment or an industrial pipeline.

Ignoring the Riser Pipe

The discharge pipe inside the well produces friction and must be included in total pipe length.

Using Nominal Pipe Diameter

Friction calculation should use actual internal diameter, not only DN or inch designation.

Selecting Only for Maximum Head

The pump must also be checked at minimum system head, where flow and absorbed motor power may increase.

Adding Too Much Safety Margin

An oversized pump is not automatically safer. It can create excessive pressure, waste energy and operate outside its preferred range.

Information Required for Submersible Pump Selection

Provide the following information when requesting a pump quotation:

  • Required flow rate in m³/h
  • Static water level
  • Dynamic water level at the required flow
  • Expected seasonal water-level variation
  • Total well depth
  • Pump setting depth
  • Well casing internal diameter
  • Discharge-point elevation
  • Required outlet pressure
  • Pipe material
  • Actual pipe internal diameter
  • Total vertical and horizontal pipe length
  • Number and type of valves and fittings
  • Water temperature
  • Water analysis
  • Sand content
  • Voltage, frequency and phase
  • Required operating hours
  • Number of duty and standby pumps
  • Required quantity

For conventional groundwater projects, review the complete Submersible Well Pump range.

Projects involving mine drainage, substantial water-level variation or high-head operation may require a specialized configuration such as the QJT Mine Submersible Pump.

Example of a Complete Pump Inquiry

A useful pump inquiry can be written as follows:

Required flow: 100 m³/h
Static water level: 22 m below ground
Dynamic water level: 38 m below ground
Pump setting depth: 75 m
Total well depth: 120 m
Discharge elevation: 12 m above ground
Required outlet pressure: 2.5 bar
Pipe internal diameter: 125 mm
Total pipe length: 150 m
Power supply: 380 V, 50 Hz, three-phase
Pumped liquid: Clean groundwater
Water temperature: 20°C
Required quantity: 2 units

With this information, the manufacturer can calculate TDH, select the hydraulic model, check motor power and provide a performance curve with the proposed duty point clearly marked.

Request a Pump Selection

Send the required flow, dynamic water level, discharge elevation, pipeline information, outlet pressure, water quality and power supply to Shanghai Weihu Pump Industry Co., Ltd.