A request such as “Please quote a 100-metre deep-well pump” is not enough for accurate pump selection.
Well depth tells the supplier how deep the borehole is, but it does not show the required flow, pumping water level, delivery pressure or pipeline resistance. Several pumps may physically fit the same well while producing very different results.
A useful RFQ should allow the manufacturer to confirm three things:
- The pump fits the well.
- It can deliver the required flow at the actual system head.
- The motor, materials and accessories suit the operating conditions.
The following information will make a deep-well pump quotation more accurate and easier to compare.
1. Required Flow Rate
State the required flow in m³/h, L/s or US gpm.
Examples:
- Required flow: 50 m³/h
- Required flow range: 80–100 m³/h
- Maximum daily demand: 1,200 m³/day, operating 12 hours per day
Daily water demand alone is not always enough. The supplier also needs to know how many hours the pump will run because:
Required hourly flow = Daily demand ÷ Available pumping hours
A project requiring 1,200 m³ per day needs 50 m³/h if the pump runs continuously for 24 hours, but it needs 100 m³/h if it operates for only 12 hours.
2. Required Head or System Information
If total dynamic head has already been calculated, provide both flow and head:
Required duty point: 100 m³/h at 84 m TDH
If TDH is unknown, provide:
- Dynamic water level
- Discharge-point elevation
- Required outlet pressure
- Vertical pipe length
- Horizontal pipe length
- Pipe internal diameter
- Pipe material
- Main valves, elbows and filters
The manufacturer can then calculate the preliminary head requirement.
Do not use total well depth as pump head. For most deep-well systems, elevation head is calculated from the dynamic water level to the delivery point, with pressure and pipeline losses added separately.
For a detailed explanation, see How to Calculate Total Dynamic Head for a Submersible Pump.
3. Static and Dynamic Water Levels
Provide both values and state the reference point used for measurement.
Example:
Static water level: 18 m below ground
Dynamic water level: 32 m below ground at 80 m³/h
Static water level is measured when the well is not pumping. Dynamic water level is measured while the pump is delivering a stated flow.
The dynamic level is more useful for pump selection because it represents the actual lifting condition during operation.
Also mention seasonal variation. If the water level falls another 10 m during the dry season, the pump must still provide sufficient flow at the higher head.
4. Well and Installation Dimensions
Provide:
- Total well depth
- Well casing internal diameter
- Pump setting depth
- Well screen position, if known
- Distance from the pump motor to the well bottom
- Any casing restriction or reduced-diameter section
The casing’s internal diameter determines the maximum pump diameter. Nominal well size is not always sufficient because casing wall thickness, joints and internal deposits can reduce the available clearance.
Example:
Well depth: 120 m
Casing internal diameter: 250 mm
Pump setting depth: 70 m
Well screen: 80–115 m
The pump should remain submerged at the lowest expected dynamic water level, while maintaining suitable clearance from the well bottom and screen.
5. Water Quality and Temperature
Describe the pumped water rather than writing only “water.”
For clean groundwater, provide any available water analysis, especially:
- pH
- Chloride concentration
- Sand content
- Total dissolved solids
- Hydrogen sulfide
- Water temperature
- Other corrosive substances
Water quality affects material selection.
Cast iron may be suitable for clean freshwater with low corrosion risk. SS304, SS316, SS316L or duplex stainless steel may be considered for more demanding water, but the grade should be selected from the actual analysis.
Do not assume that any stainless-steel pump is suitable for seawater or high-chloride water.
For compatible clean-water applications requiring stainless-steel construction, review the QJH SS304 Deep-Well Submersible Pump.
For elevated water temperature, state the normal and maximum temperatures separately. High-temperature operation may require a different motor winding, cable and sealing configuration. The QJR Hot-Water Deep-Well Submersible Pump should be selected only after the actual temperature is confirmed.
6. Power Supply
Provide the complete electrical supply:
- Voltage
- Frequency
- Number of phases
- Permitted voltage variation
- Available transformer capacity
Example:
Power supply: 380 V, 50 Hz, three-phase
Do not request a 50 Hz pump using a 60 Hz curve. Frequency changes motor speed and therefore affects pump flow, head and power.
If the project has a special voltage such as 415 V, 440 V, 460 V, 660 V or 3.3 kV, state it in the first inquiry.
7. Starting and Control Method
State how the motor will be started and controlled.
Common arrangements include:
- Direct-on-line starting
- Star-delta starting
- Soft starter
- Autotransformer starter
- Variable-frequency drive
- Automatic level control
- Pressure control
The starting method affects the motor leads, control cabinet and electrical design.
For variable-speed operation, provide the intended frequency range and control target. The supplier must check motor cooling, minimum speed, cable length and VFD compatibility.
8. Pipe and Connection Details
Provide:
- Riser-pipe diameter
- Riser-pipe material
- Total pipe length
- Outlet connection requirement
- Flange standard
- Required check valves
- Maximum permitted working pressure
Pipe diameter affects water velocity and friction loss. A pipe selected only to match the pump outlet may create unnecessary head loss.
The pressure rating should be checked against normal operating pressure, maximum system head and pump shutoff head.
9. Operating Pattern
State how the pump will operate:
- Hours per day
- Continuous or intermittent duty
- Expected starts per hour
- Seasonal or year-round operation
- One duty pump or multiple pumps
- Duty and standby arrangement
A municipal water-supply pump operating continuously should not be evaluated in the same way as an irrigation pump used for several hours per day.
For multiple pumps, explain whether they will operate alternately, in parallel or as duty and standby units.
10. Required Materials, Documents and Accessories
If the project specification has fixed requirements, include them in the RFQ.
Possible requirements include:
- Pump and motor material list
- Performance curve
- General arrangement drawing
- Motor data sheet
- Factory performance test report
- Inspection or witnessed test
- Operation manual
- Spare-parts list
- Cable length
- Control cabinet
- Riser pipe
- Check valve
- Export packing
- Certificate of origin
- Required compliance documents
Do not request certificates without confirming the applicable standard, issuing organization and destination-market requirement.
Example of an Incomplete RFQ
Please quote one 100 m deep-well pump with good quality and best price.
This request does not identify the flow, dynamic water level, discharge condition, well diameter, water quality or electrical supply. Any model selected from it would be provisional.
Example of a Complete RFQ
Please quote a deep-well submersible pump for the following duty:
Required flow: 100 m³/h
Static water level: 18 m below ground
Dynamic water level: 32 m below ground at 100 m³/h
Seasonal minimum water level: 38 m below ground
Total well depth: 120 m
Casing internal diameter: 250 mm
Pump setting depth: 70 m
Discharge point: 15 m above ground
Required outlet pressure: 2.0 bar
Riser pipe: DN125 steel pipe, 70 m
Horizontal pipe: DN125 steel pipe, 80 m
Liquid: Clean groundwater
Water temperature: 25°C
Sand content: Below 0.01%
Power supply: 380 V, 50 Hz, three-phase
Starting method: Star-delta
Operation: 12 hours per day
Quantity: 2 pumps, one duty and one standby
Documents required: Performance curve, drawing, motor data sheet and test report
Please mark the proposed duty point on the performance curve and confirm pump efficiency, absorbed power, motor rating, outlet size, materials and cable specification.
What a Complete Quotation Should Return
The supplier’s quotation should clearly state:
- Exact pump model
- Rated flow and head
- Marked performance curve
- Efficiency at the duty point
- Absorbed power
- Motor rated output
- Voltage and frequency
- Number of stages
- Pump and motor materials
- Pump dimensions
- Outlet connection
- Cable size and length
- Recommended installation depth
- Included accessories
- Test scope
- Delivery time
- Warranty terms
A quotation that lists only model, power and price is not sufficient for a proper technical comparison.
For standard groundwater installations, review the QJ Deep-Well Submersible Pump or browse the complete Submersible Well Pump range.
Send Your Deep-Well Pump RFQ
Send the flow, head, water levels, well dimensions, water analysis, electrical supply and operating requirements to Shanghai Weihu Pump Industry Co., Ltd.
We will review the duty conditions and prepare the proposed pump model, technical data and quotation.